A clinical case by our Community member Dr Edouard Cristofari
This article and its content are published under the Author’s responsibility as an expression of the Author’s own ideas and practice. Styleitaliano denies any responsibility about the visual and written content of this work.
Mechanical and biological complications have become a common reason for our daily consultations. Therefore, it is necessary to address these issues with simple and reproducible protocols.
Mrs. D. visited the clinic with an esthetic concern involving tooth 22. Three years after implant placement, she reported dissatisfaction with the unattractive, opaque border of the zirconia abutment. An esthetic treatment plan and the
placement of a new provisional restoration with natural emergence profiles were implemented to ensure long-term aesthetic, functional, and mechanical success of the new implant-supported restoration.
To optimize the outcome and minimize the number of try-ins, the OptiShade dental colorimeter (Smileline, Switzerland) was used in this case.

Fig.1
Initial situation. The crown on tooth 22 appears bulky, with its axis tilted distally.

Fig.2
A digital wax up was performed in order to correct previous crown design:
- the crown axis moved mesially
- the mesial line angle was modified to optimize symmetry with 22
- the cervical contour was flattened.

Fig.3
Creating a natural emergence profile is a challenging task that requires precise design, particularly in implant restorations. In this case, the abutment exhibits a convex contour, and such a convex emergence profile is strongly associated with an increased risk of recessions.
To prevent further vestibular recession, the abutment must be modified before taking the new impression.

Fig.4
The existing zirconia abutment was removed to modify its convex facial trans-mucosal profile and repurposed as a provisional restoration. Due to the buccolingual positioning and axial inclination of the implant, the zirconia abutment was adjusted to feature a slightly concave emergence profile.

Fig.5
After three weeks of tissue maturation, the impression could be taken.

Fig.6
The occlusal view reveals more than 2 mm of tissue surrounding the implant, achieved by reducing the bulkiness of the zirconia abutment’s contour. This increased tissue thickness ensures improved soft tissue stability.

Fig.7
Four digital intraoral scans were performed to ensure accurate data acquisition:
- An impression of both arches with the modified abutment in place and in occlusion.
- An impression of the arch using the scan body to record the implant position.
- An impression of the arch with the implant exposed, without the modified abutment.
- An impression of the modified abutment taken extraorally to replicate its trans-mucosal contour.
This sequence ensures the precise capture of gingival and emergence profiles, facilitating the adaptation of the final restoration while maintaining the trans-mucosal reference.

Fig.8
At the beginning of the session, a color assessment was performed using the OptiShade. The OptiShade colorimeter measures colors in the L*a*b* system, providing numerical data that describes colors in three dimensions. This makes the information precise and easy to share with the laboratory.

Fig.9
The Matisse software calculates the necessary recipes and mixtures of ceramic powders (dentin, enamel, internal effects) to achieve the closest color match, ensuring optimal results with a minimal number of try-ins. It is compatible with OptiShade and simplifies the layering process.

Fig.10
In this case, the screw axis emergence is positioned at the incisal border. The angulated screw channel abutment (Nobel Procera, Nobel Biocare) allows for flexible screw axis placement, ranging from 0° to 25°, while preserving the advantages of a screw-retained prosthesis.

Fig.11
The Matisse software also generates recipes for the internal effects. To prevent ceramic chipping, it is crucial to use a ceramic powder compatible with the thermal expansion coefficient of the zirconia.
The palate screw axis is clearly visible, thanks to the ASC system. The screw head features a hexalobular design and requires a special screwdriver for proper insertion. (DT Luis Saraiva, Clarity Lab Porto).

Fig.12
Final smile.

Fig.13
During the first try-in, after verifying color integration, the implant-supported restoration is torqued into place, with no signs of ischaemia present.

Fig.14
Lateral view.

Fig.15
On the OptiShade software, it is possible to compare the color of the new crown with the target color goal. DELTA E is a metric used to quantify the color difference as perceived by the human eye. In this case, the DELTA E value indicates a good to very good match. A DELTA E value of less than 1.6 represents a color difference that is undetectable to the human eye.

Fig.16
Lateral view.
Conclusions
Prosthetic retreatment of implant-supported crowns is becoming more common in our clinical practice. Simplified techniques are recommended to address daily challenges:
- The design of the abutment emergence profile is determined by the implant position and the soft tissue conditions. The emergence profile must be properly defined before the impression, using a provisional restoration.
- An appropriate digital workflow can help optimize the replication of the gingival profile.
- The introduction of a new digital color protocol has resulted in fewer color discrepancies and incorrect shade matches, improving communication with the dental technician.
Bibliography
- González-Martín O, Lee E, Weisgold A, Veltri M, Su H. Contour Management of Implant Restorations for Optimal Emergence Profiles: Guidelines for Immediate and Delayed Provisional Restorations. Int J Periodontics Restorative Dent. 2020 Jan/Feb;40(1):61-70. doi: 10.11607/prd.4422.
- Ishikawa-Nagai S, Yoshida A, Sakai M, Kristiansen J, Da Silva JD. Clinical evaluation of perceptibility of color differences between natural teeth and all-ceramic crowns. J Dent. 2009;37 Suppl 1:e57-63.
- V. Clavijo, R Recena, P.de Carvalho, W. Clavijo, L Bocabella RepliCAD—Digital Impression Strategies to Replicate the Soft Tissue Architecture and Teeth Position for Predictability in Final Restorations QDT 2021.
- Manauta J, Salat A. Layers, An atlas of composite resin stratification. Quintessence Publishing Co; 2012.
- Daas M., Cristofari E. Prothèse implantaire biomimétique: unitaire et partielle. L’information Dentaire, 2025.
- Sampaio CS, Atria PJ, Hirata R, Jorquera G. Variability of color matching with different digital photography techniques and a gray reference card. J Prosthet Dent. 2019 Feb;121(2):333-339.
- Drew A, Randi A, DiPede L, Luke A. Fracture Strength of Implant Screw-Retained All-Ceramic Crowns with the Use of the Angulated Screw Channel: A Pilot Study. Int J Periodontics Restorative Dent. 2020 Mar/Apr;40(2):245-252.
- Juntavee N, Dangsuwan C. Role of coefficient of thermal expansion on bond strength of ceramic veneered yttrium-stabilized zirconia. J Clin Exp Dent. 2018 Mar 1;10(3):e279-e286.










